The size of the ellipses depends upon the parameter ERSCALE which should be set before the data are read in so that the WORLD application can calculate the viewing area properly. This allows the ellipse size to be varied so that it can be drawn for different confidence levels.
| ERSCALE | Confidence |
| level | |
| 1.00 | 46% |
| 2.30 | 68.3% |
| 4.61 | 90% |
| 9.21 | 99% |
If the value is not specified on the command line, the current value is used. The current value is initially set to FALSE.
[The value of the global parameter PONGO_ERSCALE is used. If PONGO_ERSCALE is not defined, the default value 1.0 is used.]